Jump to the catalog

Power protection and connectivity since 1922

Find a model number · Size a battery backup

Tripp Lite
Tripp Lite OMNISMART350HG 330VA UPS 225W 4 Outlets 6ft Extension Cord
OMNISMART350HG

Tripp Lite OMNISMART350HG 330VA UPS 225W 4 Outlets 6ft Extension Cord

Medical spaces put demanding requirements on electrical connections and backup power. We built this line-interactive tower with hospital-grade receptacles and an input plug that seats securely into the wall. It maintains steady voltage through brownouts and carries the connected load on internal battery power when utility feed drops out entirely.

★★★☆☆2.8 out of 5 from 3 ratings
$392.07

Price as the listing last showed it. Listings move, so the figure on the page you land on is the one that counts at checkout.

  • 330VA/225 watts line interactive tower UPS
  • Ideal UPS protection for applications in medical patient-care areas where UL 60601-1 listed electrical medical equipment is required
  • Hospital-grade plug and outlets offer added degree of safety and reliability to input/output connections
  • 2 line phone suppression for TEL/DSL line protection
  • 4 diagnostic LEDs indicate AC present, on battery, voltage correction & battery low/replace
What it does

How this one is built

Hospital grade connections

The input cord and the output receptacles use hospital-grade hardware. The blades grip firmly into matching wall outlets and hold connected plugs securely against accidental movement or vibration around equipment carts.

Line interactive regulation

Internal circuitry trims high incoming line voltage and boosts low line voltage without switching over to the battery. Connected equipment receives stable power while the battery cells stay charged and ready for an actual blackout.

Diagnostic status lights

A front cluster of indicator lights shows what the unit is doing without making you guess. The lamps signal incoming utility power, active battery backup operation, automatic voltage correction, and when the battery needs replacement.

Phone line suppression

Network and communication connections also enter patient rooms. Dedicated pass-through jacks filter incoming telephone and data lines before the wiring reaches connected terminals, keeping utility disturbances off the secondary communication paths.

On the nameplate

These are the figures published for this unit. Where a number is missing here it was not printed on the listing, and we would rather leave the row out than fill it with a guess.

Specifications
Outlets4
Volt-amps330 VA
Watts225 W
Voltage120 V
Amps1.88 A
ConnectorNEMA 5-15
ColorWhite
Weight24 pounds
OMNISMART350HG$392.07